RM Analyzer Help

Action: LiveSet

For non-linear calculation there is necessary to evaluate more exact values. Therefore for certain  element resp. its subdivision point and lane with/without load train a load position will be written  to the certain load set, which will be treated as all other load sets in recalculation process.

SettingDescription
Action will be skipped (Option) The action will be skipped in the calculation process if the option is selected.
Action LiveSet - Nonlinear calculation of live load influence for certain element
Lane number The number of the lane that live load is to be calculated for.
Train number The number of the load train that live load is to be calculated for (option).

Press the arrow beside to choose between existing lanes and load trains.

Element:NPoint:Force Element number with its subdivision point and degree of freedom, for which the influence   will be calculated.

Press the arrow beside to choose between existing elements.

(Init) Check button INIT should be pressed, if the load set name should be initialized before
LSet Load set name, to which the influence of the lane/load train will be written
Delta-T Duration of the Action (not applicable for this action)
Description Descriptive text for the selected Action (max. 80 characters)